Xx family register allocation



  1. Unimplemented registers within a family/module are shaded
Register offset Name Min value Max value Bits/ Sign 330 331 332 333 334 335
0 Number of unnamed alarm sources 0 256 16 ü ü ü ü ü ü
1 Unnamed digital input A 0 15 13/16-16/16 ü ü ü ü ü ü
  Unnamed digital input B 0 15 9/16-12/16 ü ü ü ü ü ü
  Unnamed digital input C 0 15 5/16-8/16   ü ü ü ü ü
  Unnamed digital input D 0 15 1/16-4/16   ü ü ü ü ü
2 Unnamed digital input E 0 15 13/16-16/16     ü ü ü ü
  Unnamed digital input F 0 15 9/16-12/16     ü ü ü ü
  Unnamed digital input G 0 15 5/16-8/16     ü ü ü ü
  Unnamed digital input H 0 15 1/16-4/16     ü ü ü ü
3 Unnamed digital input I 0 15 13/16-16/16     ü ü ü ü
  Unnamed digital input J 0 15 9/16-12/16     ü ü ü ü
  Unnamed digital input K 0 15 5/16-8/16     ü ü ü ü
  Unnamed digital input L 0 15 1/16-4/16           ü
4 Unimplemented (Reserved for future digital inputs)                  
5 2130 expansion module 0 digital input A 0 15 13/16-16/16           ü
  2130 expansion module 0 digital input B 0 15 9/16-12/16           ü
  2130 expansion module 0 digital input C 0 15 5/16-8/16           ü
  2130 expansion module 0 digital input D 0 15 1/16-4/16           ü
6 2130 expansion module 0 digital input E 0 15 13/16-16/16           ü
  2130 expansion module 0 digital input F 0 15 9/16-12/16           ü
  2130 expansion module 0 digital input G 0 15 5/16-8/16           ü
  2130 expansion module 0 digital input H 0 15 1/16-4/16           ü
7 – 8 2130 expansion module 1 digital inputs A-H                 ü
9 – 10 2130 expansion module 2 digital inputs A-H                  
11-12 2130 expansion module 3 digital inputs A-H                  
13-24 Reserved for expansion modules 4-9 digital inputs                  
25 2130 expansion module 0 analogue input E low 0 15 13/16-16/16           ü
  2130 expansion module 0 analogue input E high 0 15 9/16-12/16           ü
  2130 expansion module 0 analogue input F low 0 15 5/16-8/16           ü
  2130 expansion module 0 analogue input F high 0 15 1/16-4/16           ü
26 2130 expansion module 0 analogue input G low 0 15 13/16-16/16           ü
  2130 expansion module 0 analogue input G high 0 15 9/16-12/16           ü
  2130 expansion module 0 analogue input H low 0 15 5/16-8/16           ü
  2130 expansion module 0 analogue input H high 0 15 1/16-4/16           ü

 

Xx family register allocation continued

Register offset Name Min value Max value Bits/ Sign 330 331 332 333 334 335
27 - 28 2130 expansion module 1 analogue inputs E-H                 ü
29-30 2130 expansion module 2 analogue inputs E-H                  
31-32 2130 expansion module 3 analogue inputs E-H                  
33-44 Unimplemented (Reserved for 2130 expansion module 4-9 analogue inputs E-H)                  
45 PLC function 1 0 15 13/16-16/16           ü
  PLC function 2 0 15 9/16-12/16           ü
  PLC function 3 0 15 5/16-8/16           ü
  PLC function 4 0 15 1/16-4/16           ü
46 PLC function 5 0 15 13/16-16/16           ü
  PLC function 6 0 15 9/16-12/16           ü
  PLC function 7 0 15 5/16-8/16           ü
  PLC function 8 0 15 1/16-4/16           ü
47 PLC function 9 0 15 13/16-16/16           ü
  PLC function 10 0 15 9/16-12/16           ü
  PLC function 11 0 15 5/16-8/16           ü
  PLC function 12 0 15 1/16-4/16           ü
48 PLC function 13 0 15 13/16-16/16           ü
  PLC function 14 0 15 9/16-12/16           ü
  PLC function 15 0 15 5/16-8/16           ü
  PLC function 16 0 15 1/16-4/16           ü
49 PLC function 17 0 15 13/16-16/16           ü
  PLC function 18 0 15 9/16-12/16           ü
  PLC function 19 0 15 5/16-8/16           ü
  PLC function 20 0 15 1/16-4/16           ü
50-64 Unimplemented 0 15 16            
65-255 Reserved                  

 



Alarm condition codes

Condition Meaning Displayed string
0 Disabled input None
1 Not active alarm None
2 Warning alarm Active string
3 Shutdown alarm Active string
4 Electrical trip alarm Active string
5-7 Reserved  
8 Inactive indication (no string) None
9 Inactive indication (displayed string) Inactive string
10 Active indication Active string
11-14 Reserved  
15 Unimplemented alarm None

 



Page 154 – Named Alarm Conditions